欧美性猛片xxxxx多人伦交-亚洲一区二区在线免费-日本三级日产三级国产三级-wwwxxx国产-国模大胆一区二区三区-日本少妇性生活-久久麻豆精品-五月伊人网-久久观看-婷婷午夜-男人综合网-av手机在线看-九九99九九精彩4-日本黄色播放器-新国产三级在线观看播放-草草草在线-337p粉嫩大胆噜噜噜噜69影视-亚洲视频一二区-av高清在线免费观看-99精品国产丝袜在线拍国语

Location: Home >>Project >>Smart Transmission Project

2024.10.09 Distributed fault location device for transmission lines Installation case

Author: Click:689 Time:2024-10-10

I. Project completion informationInstallation: Distributed fault location device for transmission lines? Installation caseProject time: 2024.10.0

I. Project completion information

Installation: Distributed fault location device for transmission lines  Installation case

Project time: 2024.10.09

Project completion unit: Shenzhen Dinsee Smart Technology Co.Ltd


II. Introduction to distributed fault location devices

With the increase in the demand for electricity in society, there are more and more ultra-high voltage and long-distance transmission lines, and it is especially important to reduce the outage time and ensure the reliability of power supply. When a line failure occurs, accurate and fast localization of the fault point, rapid fault handling and restoration of power supply become critical.

Distributed fault location deviceproposes a new distributed fault ranging method on the propagation characteristics of transmission lines, and proposes a brand new distributed fault ranging method on the identification of folded reflection signals, determination of singularities of traveling wave signals, identification and localization of lightning interference, GPS/BeiDou interference, and the identification and positioning of GPS/Beidou interference in the distributed fault ranging method. In the distributed fault ranging method, the key issues such as identification of refraction signal, determination of traveling wave signal singularity, identification and positioning of lightning interference, GPS/BeiDou positioning and timing, induction power collection, wireless communication in strong electromagnetic field, etc., have been thoroughly researched, and a new generation of distributed lightning positioning devices and systems have been developed.

It realizes high-frequency sampling and fast recording of signals such as fault travelling wave and refraction travelling wave, and through the background software system of the main station, it can quickly and accurately analyze the type of faults (lightning strike, discharge to tree, single-phase and inter-phase faults), and locate the position of the fault point (accuracy ≤ 300 meters).

The system also supports web access, SMS alerts and other methods, so that operation and maintenance personnel can obtain the time, type and location of the fault occurred in a timely manner, and other relevant information, greatly reducing the intensity and cost of fault inspection work, shorten the fault investigation time, and effectively improve the reliability of the power supply at the same time, but also greatly reduces the fault outage due to the direct and indirect economic losses brought about by the accident.



 




Related recommendations

The online monitoring, distributed fault location and cable online monitoring equipment for power transmission and distribution lines launched by SHENZHEN DINSEE SMART TECHNOLOGY CO.,LTD. has been widely used in Southern Power Grid and State Grid, and has achieved good results.

Record No.: Yue ICP Bei 2022070794-1 | Website Map XML Map